''Flexible Logic'' is the fanciest-schmanciest feature of rusEfi.
+
https://github.com/rusefi/rusefi/wiki/FSIO
 
 
Flexible Logic allows advanced users to get unprecedented level of configurability for custom outputs and engine control. rusEfi supports up to 16 flexible outputs, each of these could be either an on/off or PWM signal. In case of a PWM signal the frequency is defined in the
 
configuration and the duty cycle is dynamically controlled by the evaluated expression.
 
 
 
Fuel pump is already using this mechanism - see https://svn.code.sf.net/p/rusefi/code/trunk/firmware/controllers/core/le_functions.h
 
 
 
Here are some commands to try:
 
 
 
''eval "2 3 +"''
 
Prints the result of "2 + 3"
 
 
 
''eval "rpm 100 max"''
 
Prints the result of "max(100, rpm)"
 
 
 
''eval "100 200 1 if"''
 
Prints the result of "if(1, 200, 100)"
 
 
 
''set_fsio_expression 1 "rpm"''
 
Turn output #1 hi if rpm != 0
 
 
 
''set_fsio_output_pin 1 pd11''
 
Tells output #1 to use pin PD11
 
 
 
 
 
See https://svn.code.sf.net/p/rusefi/code/trunk/firmware/controllers/core/le_functions.cpp for list of available methods
 
 
 
== More Examples ==
 
 
 
''set_fsio_output_frequency 1 100''
 
Tells FSIO channel #1 to output 100Hz PWM
 
 
 
 
 
 
 
Now, let's assume we want duty cycle to be 10% if rpm is below 1000, 90% if rpm is above 5000, and have it grow linearly from 10% to 90% between 1000 rpm and 5000 rpm. The human-readable expression for that would be
 
 
 
min(0.9, max(0.1, (rpm - 1000) / 4000 * 0.8))
 
 
 
in RPN that's
 
 
 
rpm 1000 - 5000 / 0.1 max 0.9 min
 
 
 
We can use
 
 
 
''eval "rpm 1000 - 5000 / 0.1 max 0.9 min"''
 
 
 
to validate and then
 
 
 
''set_fsio_expression 1 "rpm 1000 - 5000 / 0.1 max 0.9 min"''
 
 
 
 
 
 
 
Another version of the same logic would be
 
 
 
 
 
if (rpm < 1000, 0.1, if (rpm > 5000, 0.9, 0.1 + (rpm - 1000) / 4000 * 0.8))
 
 
 
TODO
 
 
 
 
 
== FSIO parameters ==
 
 
 
FSIO expressions could be customized using 16 user-defined 'settings' which are stored within the configuration.
 
To change a setting from dev console your command is
 
''set_fsio_setting INDEX VAlUE''
 
 
 
To access for example setting #3 your FSIO expression is
 
 
 
''3 fsio_setting''
 
 
 
Please note that these indexes are starting with zero
 
 
 
== FSIO digital inputs ==
 
These feature allows you to pull toggle switches state from your fsio expressions.
 
 
 
 
 
== Case study #1: shift light ==
 
We want to turn on a warning light if RPM is above 4500
 
 
 
First we need to configure user output, let's use pin PE5 and index #3 for this example:
 
 
 
''set_fsio_output_frequency 3 0''
 
 
 
this would disable PWM on channel #3 and set this port to simple digital output mode
 
 
 
''set_fsio_output_pin 3 PE5''
 
 
 
Now we will set FSIO expression to control this output pin:
 
 
 
''set_fsio_expression 3 "rpm 4500 >"''
 
 
 
here '''3''' is the index of the output pin, and '''rpm 4500 >''' is RPN for ''rpm > 4500''
 
 
 
== Case study #2: A/C compressor control ==
 
 
 
Say we want to use PE0 as A/C toggle button, and we want A/C compressor logic to be 'if (rpm > 1200 AND A/C button is depressed) then output 200Hz @ 80% duty cycle on PB1 else output nothing on PB1'.
 
 
 
First we need to configure A/C button input pin which is currently implemented as analog input (that's a temporary hack) - see engineConfiguration->acSwitchAdc
 
 
 
''set_fsio_output_pin 3 PB1''
 
 
 
Configure output #3 to use pin PB1
 
 
 
''set_fsio_output_frequency 3 200''
 
 
 
Configure output #3 to use 200Hz PWM
 
 
 
And finally set the expression:
 
 
 
'set_fsio_expression 3 "0 80 rpm 1200 > ac_on_switch AND IF"'
 
 
 
Which is RPN for ''if(rpm > 1200 AND ac_on_switch, 80, 0)''
 
 
 
== Case study #3: digital inputs for extra devices ==
 
 
 
TODO
 
 
 
 
 
First we need to configure A/C digital input pin, we will use index 0:
 
 
 
''set_fsio_input_pin 0 PE0''
 
 
 
 
 
== Case study #4: boost controller ==
 
 
 
Solenoid-controlled boost controller would need variable duty cycle.
 
 
 
For example, let's use fsio table #3 to define the desired duty cycle:
 
 
 
[[File:Fsio_table3.png]]
 
 
 
 
 
 
 
Let's set PE11@300Hz as FSIO output #4
 
 
 
[[File:fsio_outputs.png]]
 
 
 
And now the tricky part, let's set FSIO expression on that output using the following command
 
 
 
''set_fsio_expression 4 "rpm map 3 fsio_table 100 /"''
 
 
 
Do not forget ''writeconfig''
 
 
 
 
 
''fsioinfo'' could be used to monitor output value
 
 
 
[[File:Fsioinfo.png]]
 
 
 
 
 
As for the magic expression, that's RPN for "fsio_table (3, rpm, map) / 100".
 